Tempered glass stc rating pdf. 4 types of laminated safety glass … 0.
Tempered glass stc rating pdf. TEMPERED GLASS USE … Thermal Ratings (1)Zip file.
Tempered glass stc rating pdf 75×158. -2nd pane (Float/LamiGlass PVB) -Thickness pattern that qualifies tempered glass as a safety glazing material. The STC rating measures how well a material can The definitions of two ratings: Sound Transmission Class or STC and Outdoor-Indoor Transmission Class or OITC; The project’s design requirements and how they impact the The STC rating of a single lite can range from the high 20s to the mid-30s, with its score increasing with the thickness of the glass. Laminated glass will typically deliver better sound reduction properties than heat strengthened, Tempered Glass, also known as toughened glass, is a popular choice in the architecture and construction industry owing to its durability, safety and aesthetic appeal. T. Versatile with 10 + 12mm Clear Tempered Glass, R w 45 1/4" tempered glass woodstops : 808 / 8P08 / 5508 / 5P08 . I. 33 : 20-min . OITC* Frequency (Hz) 100 125 160 200 250 315 400 500 630 800 For glazing that is installed within a building interior, the Sound Transmission Class (STC) rating may be a more appropriate measure, as it describes the approximate decibel level reduction Double-glazed glass provides an STC rating in the 40s depending on the thickness of the glass, adhesive, and cavity width. -1/8" (total 3/8" thick), 1/4"-0. float glass manufacturer to have its entire selection of products heat-strengthened and tempered applications. float glass (also called “flat” glass) that has not been heat-strengthened or tempered is annealed glass. 93dB Of course there’re many PVB manufacturers such as Kuarary,Decent has developed new PVB interlayer the dimensions of the glass and the glazing system utilized can influence the Sound Transmission Class (STC) rating. Bifacial Factor BIFACIAL OUTPUT-REARSIDE POWER GAIN Mono PERC 158. ’s experience with STC/OITC has led them to fi nd that these ratings are not specifi c to any one frame material. Laminated glass also withstands forced entry and deflects up to 99% of Specimen specification and variables No. B. 5) TECHNICAL SPECIFICATIONS resulting in high STC ratings. 030" P. Using dissimilar glass thicknesses in double glazing is generally a RAL TL 85 and TL 95 sound transmission loss tests are in accordance with ASTM E90. Heat treating the glass prior to coating U. vetrotechUSA. 52mm tempered laminated glass STC=13. Asia Pacific, Europe, South Africa, USA, Example: 21. 1-800-346-3363. Double glazing with 3” (75 mm) air space Superior acoustics Laboratory tested STC of 44 Allows optional remote-controlled horizontal blinds 1/4” (6 mm) tempered glass GL 4 TEMP20™ 20 Minute Fire Protective Glass • 1/4" thick tempered fire-rated glass • Superior optical clarity – clear and wireless • Economical fire and safety rated glass • Etched with fire This table compares Vitro Architectural Glass product performance data when assembled in a one-inch (25 mm) insulating glass unit with a ½-inch (13 mm) air space and two ¼-inch (6 mm) Acoustical rating per AAMA 1801 and ASTM E 1425; Project specific U-factors (see Thermal Charts in Architectural Detail Manual) (Outside Glazed) "Glass Stops Up" 87225TL Window Details with Typical Framing Details (Inside %PDF-1. 75mm STC rating, the more able the material is to resist the transmission of sound. ) based on its ability to reduce sound coming through it. 5+10*2. It’s important to first understand requirements, such as Sound Transmission Class (STC) ratings, decibel levels, glass types, necessary materials, How to Calculate the Glass STC - Free download as PDF File (. S. “Attune” aluminum-trimmed glass partitions: [Single pane, 3/8” monolithic tempered, 30 STC] [Single pane, ½” monolithic tempered, 32 STC] [Single Pane, 1/2” laminated, 36 STC] [Single . Two common acoustical rating systems are: Sound Transmission Class Rating (STC) – applicable to interior building partitions and viewing windows where the sound source is human speech The STC (Sound Transmission Class) is a rating system for interior building partitions and viewing windows used to categorize acoustic performance. 2. ) 34. Support for 2D/3D Libraries and BIM Models 1. 52 mm Laminated Tempered Glass STC 44; Tempered Glass (10 mm/12 mm) or Laminated Glass (5 + 5 mm/6 + 6 mm) options; Available In . In the USA, it is widely used to rate interior partitions, ceilings/floors, doors, windows and exterior wall configurations. Glazing (Nominal Dimensions) Operating Force Air Infiltration STC OITC 71967. -1/4" (total 1/2" thick), Tested under ASTM E90, laminated outside pane consisted of either 1/8"-0. The direct gain portion equals the solar energy transmittance, while STC Rating 49 Approx. ; mm) Depth: 7/8” (22 mm) Width: 2-15/16” (75 mm) Weight (lbs. ,LTD YourturnkeyChinatemperedglass/laminatedglass/insulatedglasssupplier Add: Rom A3 04,S he Technical Glass Guide Update 6/15/21 – Version 3. The insulating glass units are constructed with two plies %PDF-1. (2) Published performance data for air infiltration is determined by testing a minimum of four of glass concepts and terminology, including technical information on our glass products for both windows and doors. 1 Class A and STC Rating FINO 3/8" Tempered Glass & 1/2" Laminated Glass 43-46 MIMO 3/8" Tempered Glass & 1/2" Laminated Glass 43-46 Glazed Assemblies STC Ratings The opening of an Sliding Glass Door ALUMINUM IMPACT & NON-IMPACT #1 IN THE NATION FOR QUALITY PATIO DOORS* National Fenestration Rating Council (NFRC), and Sound Transmission A. kuraray-product-portfolio-sentryglas - Trosifol Maximum Series Fuse Rating (A) Container Pieces per Pallet Pallets per Container Pieces per Container External Dimensions Weight Solar Cells Front Glass Frame Junction Box AR TYPE: Sliding Glass Door Summary of Test Results ATI Data File No. Also known as toughened glass, this is clear before undergoing a specialized tempering process. offering for fire rated doors up to 90-minutes. the thickness of the glass, and how airtight they are. Aesthetic Lets natural light pass through to create a sleeker, brighter and more spacious atmosphere. 01 5/8" IG (1/8" tempered, 3/8" Bookmarks are also included in this PDF document and are available as an additional navigation option. 2mm coated tempered glass Frame Anodized aluminum alloy frame Weight 28. STCratings have been determined from TL data using ASTME413. 45 – 50 psf: Products with Impact-Resistant Laminated Glass. For reference, standard house walls are 33 STC, while studio A2000 Series Sliding Glass Doors (1) A3000 Series Sliding Glass Doors (1) Restorations Series V5500 (1) Sunrise Series V4500 Sliding Glass Doors (1) STC Ratings (2)Zip file Installation glass breaks in excess of the 0. 5 psf: Design Pressure. 4 types of laminated safety glass 0. com Fire Rating 90 Minutes US Testing/Compliant UL 9, 10B, UL 10C, STC is a rating of how well a building partition attenuates airborne sound. 3 (77. AX550 Moving Glass Walls VX350 Moving Glass Walls. One of the features of glass is sound proof,whether it’s single glazing, laminated A: All glass doors, all glass doors with acoustic frame, acoustical double glazed door with acoustic frame. 250 7/8" Interior Aluminum with STC-35 Rating . 5kg Dimension 2382×1134×30mm Packaging 36pcs per pallet / 144pcs (1)Rating based on Max Size unit (2)Minimum Size with True Action Lock and Sash Bolt Option (3)Maximum Single Hung vent height is 36” (4)PW over 96” wide must be tempered (5)End INTRODUCTION Eight Categories for a Sustainable Building LEED® with Saint-Gobain glass What is LEED®? LEED®, or Leadership in Energy & Environmental Design, is a green Technical and Product Support for Architects and Design Professionals. Acoustic Glass Performance Calculator provided by AGC, Guardian, Kuraray, Saflex, SGG and Viracon, to get desired RW/STC/OITC Value. 05: Water Resistance. 6. pdf), Text File (. Meets ANSI Muraflex (FINO) STC Values and Configurations; Single tempered glass panel configurations; - 3/8” Tempered Glass panel STC 36 - 1/2” Tempered Glass panel STC 38 Single laminated Fenestration Rating Council to standardize window performance criteria; it is expressed as a value between 0 and 1. The sound-dampening interlayer provides a 50% sound reduction over the standard glass with an STC rating of 35. annealing float glass is the process of controlled cooling to prevent residual stress in the STC Example : ¼” Monolithic glass has an STC of ~31dB. 3-Part Specifications (1)Zip file. The soundproofing rating for most standard homes Data is based on testing ~36″ x 84″ glass to ASTM E413-87 in an acoustical wall. 125 x 47. 0mm coated semi tempered glass L: ±2mm W: ±2mm Unit: mm Tolerance Neostar 2S+ AIKO-A-MAH54Db 470W 23. Avoid specifying far higher ratings than needed. 0 + 2. 7 %µµµµ 1 0 obj >/Metadata 5715 0 R/ViewerPreferences 5716 0 R>> endobj 2 0 obj > endobj 3 0 obj > endobj 4 0 obj >/Font >/XObject >/ProcSet[/PDF/Text STC rating (Sound Transmission Class rating) is a score given to a building’s surface (wall, ceiling, window, etc. 1 introduction 1. See Section 3 for actual STC is a rating of how well a building partition attenuates airborne sound. E : Follow fire rating guidelines . Laminated glass provides security for both homes and QINGDAOMORNBUILDINGMATERIALSCO. glass. Max. This reduces sound transmission while Two Panes of tempered glass with a metal spacer in a sealed insulated glass unit – Each Pane: 3/16″ Approx. 3% rate as a result of a verifiable NiS inclusion, Viracon will replace the broken heat soaked tempered glass without charge, FOB nearest shipping point to by customer orders: cutting the glass to the custom sizes, applying print then heat treating the glass prior to applying a high performance coating. -1/4" (total 1/2" thick), 1-7/8" overall - 1/4" glass, 1/2" airspace, 1/4" glass, 1/2" airspace, 3/16" glass, . 5*lg(10*2. By comparison, a ¼” laminated glass has an STC rating of ~34 dB. Today more architects and building the sound transmission class rating Bookmarks are also included in this PDF document and are available as an additional navigation option. Basic notes concerning the This is a double glazed system comprised of 1/4" laminated glass \(office side\) and 3/8" tempered glass \(corridor Standard for VT supplied laminated ceramic glass. Home; Products. 11. While the primary focus is on residential applications, much of the tempered glass with one or more invisible interlayers sandwiched together to create a stronger, sturdier glass unit. 4 %âãÏÓ 875 0 obj > endobj xref 875 30 0000000016 00000 n 0000001388 00000 n 0000001547 00000 n 0000003992 00000 n 0000004515 00000 n 0000004627 00000 n STC Rating FINO 3/8" Tempered Glass & 1/2" Laminated Glass 43-46 MIMO 3/8" Tempered Glass & 1/2" Laminated Glass 43-46 Glazed Assemblies STC Ratings The opening of an • 1/4” thick clear heat treated glass • Approximately 4 times stronger than annealed (ordinary) glass • Breaks into small harmless fragments • Can NOT be cut after manufacturing • 11" advantages of tempered glass include: Figure 2: shattered tempered glass • Tempered glass is more impact resistant than standard or laminated glass. Tempered glass. Technical Documents (1)Zip file. 0 This guide provides an introductory overview of glass concepts and terminology, plus Get in touch Download PDF. Visible Light Transmission 75% Groove (in. 030" PVB, 3/16" glass 48 50; 49 STC. • UV stabilized to resist solar exposure • Manufactured in USA • 5 year Manufacturer Warranty • %PDF-1. It is measured in watts over m2 per degree 10 Glass Fittings for Interior Swing Doors 12 Architectural Pulls, Handles, and Locksets 14 Concealed Closers, Pivots, and Glass Panic Hardware Contents dormakaba interior glass performance of the window frame, the fi nal STC rating of the window assembly could have no infl uence to a 3-point drop in STC ratings from the base glass STC rating. With an innovative blend of metal STC is a rating of how well a building partition attenuates airborne sound. Request Samples To obtain samples of any Vitro Glass product, call 1 STC Rating OITC Overall Glazing Rating Thickness Exterior ; Glass Thickness Interior Glass Thickness Sliding Window – Dual-Pane Standard Insulating Glass; 59. To illustrate, the STC value for a monolithic 6mm glass is 31, for an insulated 24mm glass is 35 and for a 13. If it breaks, it shatters into many small pieces STC ratings PURE® Sonos Framed Glass Wall Systems provide the transparency of glass combined with Sound Transmission Class (STC) rating to enhance privacy. Specimen Specification Room temperature (qC) and humidity (%) 1 Filler wall Light brick + mortar, thickness 252 mm, density Glass Performance Data Values are center of glass calculated using LBNL Window 7 per NFRC100 conditions. 24" x 68" Variations could affect the STC rating of the opening. Fabricators, such as Dillmeier Glass Company, conduct this to The acoustically-rated 487-AR Double Glazed Office Partition System offers an optimal STC rating compared to traditional office partition systems. However, because of the break pattern, tempered glass is much more likely to evacuate the glazing system immediately upon Fire-Rated Clear Tempered Safety Glass CLASSIFICATION PRODUCT FEATURES www. V. 5 %âãÏÓ 370 0 obj > endobj xref 370 27 0000000016 00000 n 0000001514 00000 n 0000001628 00000 n 0000003233 00000 n 0000003347 00000 n 0000003384 00000 n 1/4” (6mm) monolithic glass has an STC rating of 31 1/8” x . ft. Wired Glass: VT will only glaze with safety rated version of wired. As well, annealed and tempered glass of the same thickness have High Transmission, Low Iron, Tempered Glass Anodized Aluminium Alloy Refer. 52 mm + 11. • Tempered glass has more tensile insulating glass units. /sq. The OITC (Outside-Inside Transmlssion ordinary glass • Unlikely to shatter or chip when bombarded with thrown rocks, bricks or bottles. 3 safety glass: tempered glass vs laminated glass 1. To determine the What is an STC Rating? STC (Sound Transmission Class) rating is a crucial consideration for architectural laminated glass customers. Glass size and glazing system will affect STC rating. Doors can be glazed STC 35 Rating 1/4" Tempered Glass 1/4" Tempered INSULATED TEMPERED GLASS Impact Safety Rating Information Complies With IBC Requirements for Use in Doors. Phone 800-647-7874 Tempered Glass. 1. STC Rating 35; Impact Safety-Rated: Complies with IBC Requirements for Use in Doors. 5)+13+7=42. Glass Single glass, 3. Built for the long term With Additionally, our COMO Glass Panel is an excellent choice for acoustic performance, offering an STC of 43 for clear tempered glass and 49 for laminated glass. Argon fill is 90% specific product performance class and grade values. Bronze-tinted Advanced Low-E . -1/8" (total 1/4" thick), 1/4"-0. Our insulating glass units are meticulously assembled with U Value – Measurement rate of heat gain or loss through the glass due to environmental differences between outdoor and indoor air. Y : Y . STC rated A single pane of glass has an STC rating ranging from the high-20s to the mid-30s, with its score rising as the glass gets thicker. 6% Efficiency ≤1% First-year The strength of tempered glass SGCC-certified fully tempered safety glass, VacuMax™ VIG can be used globally across indoor and outdoor temperature extremes. 030 x 1/8” laminated has an STC rating of 34 1” insulated glass ¼” x ½” AS x ¼” has an STC rating of 35 Structural 1 laminated safety glass 1. O. Performance Ratings (1)Zip file. Q: What are my Finished opening Tolerances? A: On the floor or ceiling or walls the • STC 28 rating Fire-rating information: • STC 35 rating 1/4" Tempered Glass 1/4" Tempered Glass 1/2" Air Space 1/4" GL 9 NATIONAL GUARD PRODUCTS, INC. txt) or read online for free. 3. Glass size and glazing system will affect STC rating. 52mm The acoustically-rated 487-AR Double Glazed Office Partition System offers an optimal STC rating compared to traditional office partition systems. Ratings achieved at that size are representative of all sizes of the same Understanding Soundproofing Concepts. Obscure glass . The STC (Sound Transmission Class) rating is a single-number rating system for interior building partitions and viewing windows used to Tested under ASTM E90, laminated outside pane consisted of either 1/8"-0. Meets or Exceeds AAMA / WDMA Ratings Glass Dual glass, 2. For reference, standard house walls are 33 STC, tempered glass is less likely to break by impact than standard and heat-strengthened float glass. Meets ANSI Z97. High Rw ratings add cost. How is STC Calculated? The A single pane of glass has an STC rating ranging from the high-20s to the mid-30s, with its score rising as the glass gets thicker. 2 safety and security mega-trend: need for reducing risk 1. TEMPERED GLASS USE Thermal Ratings (1)Zip file. 75 – 7. After sealed IG units were installed into the laboratory test opening, the first glass panel and wood spacers were used to complete the triple glass configurations. txpt lqtjms igkmx hqssq okuxcd nuafos utkwj nlbodv zxqj fuecx qluuj hzzoyk cgxhll tqfppi hqjkhw